代码拉取完成,页面将自动刷新
同步操作将从 zengfr繁荣/easymodbus4j 强制同步,此操作会覆盖自 Fork 仓库以来所做的任何修改,且无法恢复!!!
确定后同步将在后台操作,完成时将刷新页面,请耐心等待。
easymodbus4j A high-performance and ease-of-use implementation of the Modbus protocol written in Java netty support for modbus 4 mode client/server.
easymodbus4j 特点: 1、Netty NIO high performance高性能. 2、Modbus Function sync/aync 同步/异步非阻塞。 3、Modbus IoT Data Connector Supports工业物联网平台IoT支持。 4、完全支持4种部署模式: 服务器master,客户端slave,服务器slave,客户端master。 5、友好的调试以及日志支持bit\bitset\byte\short\int\float\double。 6、Supports Function Codes: Read Coils (FC1) Read Discrete Inputs (FC2) Read Holding Registers (FC3) Read Input Registers (FC4) Write Single Coil (FC5) Write Single Register (FC6) Write Multiple Coils (FC15) Write Multiple Registers (FC16) Read/Write Multiple Registers (FC23)
#Example Code in https://github.com/zengfr/easymodbus4j
Repositories Central Sonatype Mvnrepository easymodbus4j
快速开发Quick Start:
第一步step1:
maven:
<dependency>
<groupId>com.github.zengfr</groupId>
<artifactId>easymodbus4j</artifactId>
<version>0.0.3</version>
</dependency>
第二步step2:
2.1 if master 实现implement ResponseHandler接口 see easymodbus4j-example:ModbusMasterResponseHandler.java
2.2 if slave 实现implement RequestHandler接口 see easymodbus4j-example:ModbusSlaveRequestHandler.java
第三步step3:
modbusServer = ModbusServerFactory.getInstance().createServer4Master(port, responseHandler);
modbusClient = ModbusClientFactory.getInstance().createClient4Slave(host,port, requestHandler);
modbusClient = ModbusClientFactory.getInstance().createClient4Master(host, port, responseHandler);
modbusServer = ModbusServerFactory.getInstance().createServer4Slave(port, requestHandler);
第四步step4:
4.1 how to send a request ?
ChannelSender sender = ChannelSenderFactory.getInstance().get(channel);
sender.readCoils(...)
sender.readDiscreteInputs(...)
sender.writeSingleRegister(...)
4.2 how to show log?
see ModbusMasterResponseHandler.java
ModbusFrameUtil.showFrameLog(logger, channel, frame);
Example run startup: 1、unzip file easymodbus4j-release.zip. 2、for modbus master mode:open autosend.txt file in dir or autosend.txt rsourcefile in easymodbus4j.jar 3、for modbus master mode:edit autosend.txt file 4、start startup.bat. 5、you also can edit *.bat for modbus master/salve mode: . 说明: 1、解压缩zip文件到文件夹 2、java程序 运行不了 则安装jdk8. 3、解压后4个bat文件 对应 服务器master,客户端slave,服务器slave,客户端master 4种模式. 4、Master模式 可以设置autosend.txt文件,定时发送读写请求。 5、记事本打开bat文件可以编辑相关参数,如定时延时发送时间以及详细日志开关。
此处可能存在不合适展示的内容,页面不予展示。您可通过相关编辑功能自查并修改。
如您确认内容无涉及 不当用语 / 纯广告导流 / 暴力 / 低俗色情 / 侵权 / 盗版 / 虚假 / 无价值内容或违法国家有关法律法规的内容,可点击提交进行申诉,我们将尽快为您处理。