远程调用斑马打印机打印标签!
部署需要满足下面条件:
双击打开 zebra_webapi.exe
初次会在根目录创建配置文件config.toml:
[config]
[config.App]
HttpPort = 9022
PrinerIpPort = '192.168.1.10:9100'
[config.Zaplog]
Director = 'runtime/log'
Level = 'debug'
HttpPort:服务端口
PrinerIpP:打印机地址 9100为默认端口 一般不改
再次启动即可开启成功!
在目录cmd下运行:
zebra_webapi install
接口地址:http://[url]/print ,url为服务所在地址和配置的端口
方法:POST
body写入:
{
"name":"ts11t", "data":{"title":"哈哈哈哈","title2":"111"},
}
调用接口后,会在程序目录下创建默认模板:
^XA
^LH00,00^FS
^SEE:GB18030.DAT
^CI26
^CWJ,E:SIMSUN.TTF^FS
^FO40,40^GFA,1113,4400,44,:Z64: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:3BEC
^FO220,160^AJN,50,50^FD物料信息^FS
^FO50,260^AJN,30,30^FD 时间:{datetime} ^FS
^FO50,320^AJN,30,30^FD 重量:{qty} {uint} ^FS
^FO50,380^AJN,30,30^FD 位置:{pos} ^FS
^FO50,440^AJN,30,30^FD 备注:{comment} ^FS
^FO10,10^GB600,600,5^FS
^MD20
^PQ1,0,0,N
^XZ
返回值:
{
"code": 0, //0表示成功,1:表示有错误
"data": {},
"msg": "success" //错误信息或者成功
}
接口地址:http://[url]/print_zpl ,url为服务所在地址和配置的端口
方法:POST
body写入:
{
"data":"^XA^FO50,50^A0N,50,50^FDHello, World!^FS^XZ"
}
wincc按钮天添加一个vbs脚本动作
写入如下脚本:
'keys 是对应模板里的变量名 {title},{name}
'values 对应的值
Dim keysT,valuesT,name
'打印模板名称
name = "test"
Dim url,paramsStr
url = "http://192.168.3.121:9022/print"
paramsStr = "{""name"":""" + name + """,""data"":{"
'拼接字符串
'title是模板里的字段,后面为值
paramsStr = paramsStr + """" + "title" + """:""" + HMIRuntime.Tags("TEXT_02").Read + ""","
paramsStr = paramsStr + """" + "title1" + """:""" + HMIRuntime.Tags("TEXT_02").Read + ""","
paramsStr = paramsStr + """" + "title2" + """:""" + HMIRuntime.Tags("TEXT_02").Read + ""","
paramsStr = paramsStr + """" + "title3" + """:""" + HMIRuntime.Tags("TEXT_02").Read + ""","
'wincc for 无法使用
' For i = 0 To 1
' paramsStr = paramsStr + """" + keys(i) + """:""" + values(i) + ""","
'Next
paramsStr = Left(paramsStr, Len(paramsStr) - 1) + "}}"
Dim oauth_http,HttpRequest
Set oauth_http=CreateObject("MSXML2.XMLHTTP")
oauth_http.Open "POST",url,False
oauth_http.setRequestHeader "Content-Type","application/json"
oauth_http.Send(paramsStr)
HttpRequest = oauth_http.responseText
Msgbox HttpRequest
Set oauth_http=Nothing
ebr里使用和windows直接使用vbs一样
Function HttpRequest(name,keys,values)
Dim url,paramsStr
url = "http://127.0.0.1:9022/print"
paramsStr = "{""name"":""" + name + """,""data"":{"
For i = 0 To UBound(keys)
paramsStr = paramsStr + """" + keys(i) + """:""" + values(i) + ""","
Next
paramsStr = Left(paramsStr, Len(paramsStr) - 1) + "}}"
Dim oauth_http
Set oauth_http=CreateObject("Microsoft.XMLHttp")
oauth_http.Open "POST",url,False
oauth_http.setRequestHeader "Content-Type","application/json"
oauth_http.Send(paramsStr)
HttpRequest = oauth_http.responseText
Set oauth_http=nothing
End Function
'keys 是对应模板里的变量名 {title},{name}
'values 对应的值
Dim keys,values
keys = Array("title","name")
values = Array("张三","18")
MsgBox(HttpRequest("test",keys,values))
数字代表点数,203dpi = 8dots/mm
比如:^FO330表示 203dpi的打印机: 330/8mm
下面是摘录的官方文档,更多内容查看官方文档
^LH – Label Home The ^LH command sets the label home position. The default home position of a label is the upper-left corner (position 0,0 along the x and y axis). This is the axis reference point for labels. Any area below and to the right of this point is available for printing. The ^LH command changes this reference point. For instance, when working with preprinted labels, use this command to move the reference point below the preprinted area. This command affects only fields that come after it. It is recommended to use ^LH as one of the first commands in the label format. Format: ^LHx,y
^CW – Font Identifier All built-in fonts are referenced using a one-character identifier. The ^CW command assigns a single alphanumeric character to a font stored in DRAM, memory card, EPROM, or Flash. If the assigned character is the same as that of a built-in font, the downloaded font is used in place of the built-in font. The new font is printed on the label wherever the format calls for the built-in font. If used in place of a built-in font, the change is in effect only until power is turned off. If the assigned character is different, the downloaded font is used as an additional font. The assignment remains in effect until a new command is issued or the printer is turned off. Format: ^CWa,d:o.x
^A@ – Use Font Name to Call Font The ^A@ command uses the complete name of a font, rather than the character designation used in ^A. Once a value for ^A@ is defined, it represents that font until a new font name is specified by ^A@. Format: ^A@o,h,w,d:f.x Parameter Details o = field orientation Values: N = normal R = rotates 90 degrees (clockwise) I = inverted 180 degrees B = read from bottom up, 270 degrees Default: N or the last ^FW value h = character height
^FD – Field Data The ^FD command defines the data string for a field. The field data can be any printable character except those used as command prefixes (^ and ~). In RFID printers, it can also be used to specify passwords to write to tags. Format: ^FDa Comments The ^ and ~ characters can be printed by changing the prefix characters—see ^CD ~CD on page 130 and ^CT ~CT on page 142. The new prefix characters cannot be printed. Characters with codes above 127, or the ^ and ~ characters, can be printed using the ^FH and ^FD commands. • ^CI13 must be selected to print a backslash (). For information on using soft hyphens, see Comments on the ^FB command on page 164. Parameters Details a = • data to be printed (all printers), or • a password to be written to a RFID tag (rfid printers) Values: any data string up to 3072 bytes Default: none—a string of characters must be entered
^FS – Field Separator The ^FS command denotes the end of the field definition. Alternatively, ^FS command can also be issued as a single ASCII control code SI (Control-O, hexadecimal 0F). Format: ^FS
^FO – Field Origin The ^FO command sets a field origin, relative to the label home (^LH) position. ^FO sets the upper- left corner of the field area by defining points along the x-axis and y-axis independent of the rotation. Format: ^FOx,y,z Comments If the value entered for the x or y parameter is too high, it could position the field origin completely off the label. Parameters Details x = x-axis location (in dots) Values: 0 to 32000 Default: 0 y = y-axis location (in dots) Values: 0 to 32000 Default: 0 z = justification The z parameter is only supported in firmware versions V60.14.x, V50.14.x, or later. Values: 0 = left justification 1 = right justification 2 = auto justification (script dependent) Default: last accepted ^FW value or ^FW default This command interacts with the field direction parameter of ^FP and with the rotation parameter of ^A. For output and examples, see Field Interactions on page 1369. The auto justification option might cause unexpected results if variable fields or bidirectional text are used with ^FO. For the best results with bidirectional text and/or variable fields, use either the left of right justification option.
^MD – Media Darkness The ^MD command adjusts the darkness relative to the current darkness setting. Format: ^MDa Comments The ~SD command value, if applicable, is added to the ^MD command. Parameters Details a = media darkness level Values: -30 to 30, depending on current value Initial Value at Power Up: 0 If no value is entered, this command is ignored
^PQ – Print Quantity The ^PQ command gives control over several printing operations. It controls the number of labels to print, the number of labels printed before printer pauses, and the number of replications of each serial number. Format: ^PQq,p,r,o,e If the o parameter is set to Y, the printer cuts but does not pause, and the printer does not pause after every group count of labels has been printed. With the o parameter set to N (default), the printer pauses after every group count of labels has been printed. Parameters Details q = total quantity of labels to print Values: 1 to 99,999,999 Default: 1 p = pause and cut value (labels between pauses) Values: 1 to 99,999,999 Default: 0 (no pause) r = replicates of each serial number Values: 0 to 99,999,999 replicates Default: : 0 (no replicates) o = override pause count Values: N = no Y = yes Default: N e = cut on error label (RFID void is an error label) Values: N = no - if a cutter is installed, a cut will be made after a voided RIFD label ONLY if a cut would be made after the non-voided label and this was the last retry. Y = yes - if a cutter is installed, a cut will be made after ANY voided RFID label. Default: Y
^GB – Graphic Box The ^GB command is used to draw boxes and lines as part of a label format. Boxes and lines are used to highlight important information, divide labels into distinct areas, or to improve the appearance of a label. The same format command is used for drawing either boxes or lines. Format: ^GBw,h,t,c,r For the w and h parameters, keep in mind that printers have a default of 6, 8, 12, or 24 dots/millimeter. This comes out to 153, 203, 300, or 600 dots per inch. To determine the values for w and h, calculate the dimensions in millimeters and multiply by 6, 8, 12, or 24. If the width and height are not specified, you get a solid box with its width and height as specified by value t. The roundness-index is used to determine a rounding-radius for each box. Formula: rounding-radius = (rounding-index / 8) * (shorter side / 2) where the shorter side is the lesser of the width and height (after adjusting for minimum and default values). Parameters Details w = box width (in dots) Values: value of t to 32000 Default: value used for thickness (t) or 1 h = box height (in dots) Values: value of t to 32000 Default: value used for thickness (t) or 1 t = border thickness (in dots) Values: 1 to 32000 Default: 1 c = line color Values: B = black W = white Default: B r = degree of corner- rounding Values: 0 (no rounding) to 8 (heaviest rounding) Default: 0
^XG – Recall Graphic The ^XG command is used to recall one or more graphic images for printing. This command is used in a label format to merge graphics, such as company logos and piece parts, with text data to form a complete label. An image can be recalled and resized as many times as needed in each format. Other images and data might be added to the format. Format: ^XGd:o.x,mx,my Parameters Details d = source device of stored image Values: R:, E:, B:, and A: Default: search priority (R:, E:, B:, and A:) o = name of stored image Values: 1 to 8 alphanumeric characters Default: if a name is not specified, UNKNOWN is used x = extension l Fixed Value: .GRF mx = magnification factor on the x- axis Values: 1 to 10 Default: 1 my = magnification factor on the y- axis Values: 1 to 10 Default: 1 Example: This is an example of using the ^XG command to recall the image SAMPLE.GRF from DRAM and print it in five different sizes in five different locations on the same label: ^XA ^FO100,100^XGR:SAMPLE.GRF,1,1^FS ^FO100,200^XGR:SAMPLE.GRF,2,2^FS ^FO100,300^XGR:SAMPLE.GRF,3,3^FS ^FO100,400^XGR:SAMPLE.GRF,4,4^FS ^FO100,500^XGR:SAMPLE.GRF,5,5^FS ^XZ
^GF – Graphic Field The ^GF command allows you to download graphic field data directly into the printer’s bitmap storage area. This command follows the conventions for any other field, meaning a field orientation is included. The graphic field data can be placed at any location within the bitmap space. Format: ^GFa,b,c,d,data Parameters Details a = compression type Values: A = ASCII hexadecimal (follows the format for other download commands) B = binary (data sent after the c parameter is strictly binary) C = compressed binary (data sent after the c parameter is in compressed binary format. The data is compressed on the host side using Zebra’s compression algorithm. The data is then decompressed and placed directly into the bitmap.) Default: A b = binary byte count Values: 1 to 99999 This is the total number of bytes to be transmitted for the total image or the total number of bytes that follow parameter d. For ASCII download, the parameter should match parameter c. Out-of-range values are set to the nearest limit. Default: command is ignored if a value is not specified c = graphic field count Values: 1 to 99999 This is the total number of bytes comprising the graphic format (width x height), which is sent as parameter d. Count divided by bytes per row gives the number of lines in the image. This number represents the size of the image, not necessarily the size of the data stream (see d). Default: command is ignored if a value is not specified d = bytes per row Values: 1 to 99999 This is the number of bytes in the downloaded data that comprise one row of the image. Default: command is ignored if a value is not specified data = data Values: ASCII hexadecimal data: 00 to FF A string of ASCII hexadecimal numbers, two digits per image byte. CR and LF can be inserted as needed for readability. The number of two-digit number pairs must match the above count. Any numbers sent after count is satisfied are ignored. A comma in the data pads the current line with 00 (white space), minimizing the data sent. ~DN or any caret or tilde character prematurely aborts the download. Binary data: Strictly binary data is sent from the host. All control prefixes are ignored until the total number of bytes needed for the graphic format is sent. Example: This example downloads 8,000 total bytes of data and places the graphic data at location 100,100 of the bitmap. The data sent to the printer is in ASCII form.