MyEMS Modbus TCP Service

Introduction

This service is a component of MyEMS to acquire data from Modbus TCP devices.

Prerequisites

mysql-connector-python

modbus_tk

schedule

python-decouple

Quick Run for Development

cd myems/myems-modbus-tcp
pip install -r requirements.txt
cp example.env .env
chmod +x run.sh
./run.sh

Installation

Option 1: Install myems-modbus-tcp on Docker

In this section, you will install myems-modbus-tcp on Docker.

  • Copy source code to root directory

On Windows:

cp -r myems/myems-modbus-tcp c:\
cd c:\myems-modbus-tcp

On Linux:

cp -r myems/myems-modbus-tcp /
cd /myems-modbus-tcp
  • Create .env file based on example.env file

Manually replace 127.0.0.1 with real HOST IP address.

cp example.env .env
  • Build a Docker image
docker build -t myems/myems-modbus-tcp .

To build for multiple platforms and not only for the architecture and operating system that the user invoking the build happens to run. You can use buildx and set the --platform flag to specify the target platform for the build output, (for example, linux/amd64, linux/arm64, or darwin/amd64).

docker buildx build --platform=linux/amd64 -t myems/myems-modbus-tcp .
  • Run a Docker container on Linux (run as superuser)
docker run -d -v /myems-modbus-tcp/.env:/code/.env:ro --log-opt max-size=1m --log-opt max-file=2 --restart always --name myems-modbus-tcp myems/myems-modbus-tcp
  • Run a Docker container on Windows (Run as Administrator)
docker run -d -v c:\myems-modbus-tcp\.env:/code/.env:ro --log-opt max-size=1m --log-opt max-file=2 --restart always --name myems-modbus-tcp myems/myems-modbus-tcp
  • -d Run container in background and print container ID

  • -v If you use -v or --volume to bind-mount a file or directory that does not yet exist on the Docker host, -v creates the endpoint for you. It is always created as a directory. The ro option, if present, causes the bind mount to be mounted into the container as read-only.

  • --log-opt max-size=2m The maximum size of the log before it is rolled. A positive integer plus a modifier representing the unit of measure (k, m, or g).

  • --log-opt max-file=2 The maximum number of log files that can be present. If rolling the logs creates excess files, the oldest file is removed. A positive integer.

  • --restart Restart policy to apply when a container exits

  • --name Assign a name to the container

The absolute path before colon is for path on host and that may vary on your system. The absolute path after colon is for path on container and that CANNOT be changed. By passing .env as bind-mount parameter, you can change the configuration values later. If you changed .env file, restart the container to make the change effective.

  • Immigrate the Docker container

To immigrate the container to another computer,

  • Export image to tarball file
docker save --output myems-modbus-tcp.tar myems/myems-modbus-tcp
  • Copy the tarball file to another computer, and then load image from tarball file
docker load --input .\myems-modbus-tcp.tar

Installation Option 2: Online install on Ubuntu server with internet access

In this section, you will install myems-modbus-tcp on Ubuntu Server with internet access.

cp -r myems/myems-modbus-tcp /myems-modbus-tcp
cd /myems-modbus-tcp
pip install -r requirements.txt -i http://mirrors.aliyun.com/pypi/simple/ --trusted-host mirrors.aliyun.com

Copy exmaple.env file to .env and modify the .env file:

cp /myems-modbus-tcp/example.env /myems-modbus-tcp/.env
nano /myems-modbus-tcp/.env

Setup systemd service:

cp myems-modbus-tcp.service /lib/systemd/system/

Enable the service:

systemctl enable myems-modbus-tcp.service

Start the service:

systemctl start myems-modbus-tcp.service

Monitor the service:

systemctl status myems-modbus-tcp.service

View the log:

cat /myems-modbus-tcp.log

Installation Option 3: Offline install on Ubuntu server without internet access

Download and install MySQL Connector:

cd ~/tools
wget https://cdn.mysql.com//Downloads/Connector-Python/mysql-connector-python-8.0.28.tar.gz
tar xzf mysql-connector-python-8.0.28.tar.gz
cd ~/tools/mysql-connector-python-8.0.28
python3 setup.py install

Download and install Schedule

cd ~/tools
git clone https://github.com/dbader/schedule.git
cd ~/tools/schedule
python3 setup.py install

Download and install Python Decouple

cd ~/tools
git clone https://github.com/henriquebastos/python-decouple.git
cd ~/tools/python-decouple
python3 setup.py  install

Download and install modbus-tk

cd ~/tools
git clone https://github.com/pyserial/pyserial.git
cd ~/tools/pyserial
python3 setup.py install
git clone https://github.com/ljean/modbus-tk.git
cd ~/tools/modbus-tk
python3 setup.py install

Install myems-modbus-tcp service

cp -r myems/myems-modbus-tcp /myems-modbus-tcp
cd /myems-modbus-tcp

Create .env file based on example.env and edit the .env file if needed:

cp /myems-modbus-tcp/example.env /myems-modbus-tcp/.env
nano /myems-modbus-tcp/.env

Setup systemd service:

cp myems-modbus-tcp.service /lib/systemd/system/

Enable the service:

systemctl enable myems-modbus-tcp.service

Start the service:

systemctl start myems-modbus-tcp.service

Monitor the service:

systemctl status myems-modbus-tcp.service

View the log:

cat /myems-modbus-tcp.log

Add Data Sources and Points in MyEMS Admin UI

NOTE: If you modified Modbus TCP data sources and points, please restart this service:

systemctl restart myems-modbus-tcp.service

Input Data source protocol:

modbus-tcp

Data source connection example:

{"host":"10.9.67.99","port":502}

Point address example:

{"slave_id":1, "function_code":3, "offset":0, "number_of_registers":2, "format":"<f", "byte_swap":true}

Address

slave_id

The slave ID

function_code

    01 (0x01) Read Coils
    02 (0x02) Read Discrete Inputs
    03 (0x03) Read Holding Registers
    04 (0x04) Read Input Registers
    23 (0x17) Read/Write Multiple registers

offset

The starting register address specified in the Request PDU

number_of_registers

The number of registers specified in the Request PDU

format

Use python3 library struct to format bytes. Python bytes objects are used to hold the data representing the C struct and also as format strings (explained below) to describe the layout of data in the C struct.

The optional first format char indicates byte order, size and alignment: @: native order, size & alignment (default) =: native order, std. size & alignment <: little-endian, std. size & alignment >: big-endian, std. size & alignment !: same as >

The remaining chars indicate types of args and must match exactly; these can be preceded by a decimal repeat count: x: pad byte (no data); c:char; b:signed byte; B:unsigned byte; ?: _Bool (requires C99; if not available, char is used instead) h:short; H:unsigned short; i:int; I:unsigned int; l:long; L:unsigned long; f:float; d:double.

Special cases (preceding decimal count indicates length): s:string (array of char); p: pascal string (with count byte). Special cases (only available in native format): n:ssize_t; N:size_t; P:an integer type that is wide enough to hold a pointer.

Special case (not in native mode unless 'long long' in platform C): q:long long; Q:unsigned long long

Whitespace between formats is ignored.

byte_swap

A boolean indicates whether or not to swap adjacent bytes.
Swap adjacent bytes of 32bits(4bytes) or 64bits(8bytes). This is not for little-endian and big-endian swapping, and use format for that. The option is effective when number_of_registers is ether 2(32bits) or 4(64bits), else it will be ignored.